Skip to content

Victron 12-165 GEL (24V Bank)

  • Type: 12V 165Ah GEL (VRLA), configured as 24V bank
  • Use: Legacy/aux battery bank for 24V systems

Installed

  • Quantity: 4 units installed
  • Bank arrangement: 2S2P (two series pairs in parallel, 24V nominal)

Configuration Notes

  • Two 12V 165Ah GEL batteries in series for 24V nominal, with two such series strings in parallel (2S2P).
  • Observe Victron recommended charge voltages for GEL chemistry.
  • Ensure temperature-compensated charging if available.

Capacity

  • Per battery: 12V × 165Ah = 1,980Wh (1.98kWh)
  • Bank topology: 2S2P → 24V nominal, Ah sums in parallel: 165Ah × 2 = 330Ah
  • Total energy (theoretical): 24V × 330Ah = 7,920Wh (7.92kWh)
  • Usable energy (typical guidance for GEL):
  • 50% DoD (long life): ≈ 3.96kWh
  • 80% DoD (shorter life): ≈ 6.34kWh

Datasheet

  • External link: https://www.victronenergy.com/upload/documents/Datasheet-GEL-and-AGM-Batteries-EN.pdf
  • Local copy: Datasheet (PDF)